Kort informasjon 10 ml Monitor the Concentration of Reduced Forms of NADH and NADPH. Highly sensitive and rapid bioluminescent assay. Easily adapted for high-throughput format.
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The in vitro enzyme-based NAD(P)H-Glo™ Detection System is a homogeneous, bioluminescent assay that quantitatively monitors the concentration of the reduced forms of nicotinamide adenine dinucleotides, NADH and NADPH, and does not discriminate between them. The oxidized forms, NAD+ and NADP+, are not detected and do not interfere with quantitation.In the presence of NAD(P)H, a reductase enzyme reduces a proluciferin reductase substrate to form luciferin. Luciferin then is quantified using Ultra-Glo™ Recombinant Luciferase, and the light signal produced is proportional to the amount of NAD(P)H in the sample. The reductase and luciferase reactions are initiated by adding an equal volume of a single reagent, which contains reductase, proluciferin Reductase Substrate and Ultra-Glo™ Recombinant Luciferase, to a NAD(P)H-containing sample.The assay is rapid, requiring only a 40- to 60-minute incubation, has a broad linear range and high signal-to background ratio. The assay is well suited to measuring NAD(P)H production or consumption in high-throughput formats.|

Broad Linear Range: The NAD(P)H-Glo(TM); Detection System detects 0.1 mM to 25 mM NAD(P)H.
High Sensitivity: The limit of detection is ≤0.1 mM NADH, with a maximum assay window (i.e., signal-to-background ratio) of 250. The system detects 1 mM with a signal higher than fivefold over background.
Automation Compatible: The add-and-read format is compatible with automated and high-throughput protocols. Reactions are scalable and can be performed at low volumes in 96-, 384- and 1536-well plates.
Reliability and Reproducibility: The NAD(P)H-Glo(TM); Detection System routinely yields Z factors more than0.7.
Stable Signal: The glow-type signal is stable, with a half-life greater than two hours, allowing batch plate processing.
Luminescence-Based NAD(P)H Detection: The luminescent format avoids fluorescent interference due to reagents and test compounds sometimes seen in fluorescent assays.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store all components at -20 C (-30 C to -10 C).|

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding