Promega

PowerPlex 16 HS System, 400rxn

Varenummer: DC2100
Kort informasjon
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The PowerPlex 16 HS System is a multiplex STR system for use in DNA typing. This system co-amplifies the loci Penta E, D18S51, D21S11, TH01, D3S1358 (labeled with fluorescein); FGA, TPOX, D8S1179, vWA and Amelogenin (labeled with TMR); Penta D, CSF1PO, D16S539, D7S820, D13S317 and D5S818 (labeled with JOE). This multiplex includes all 13 CODIS STR markers, Amelogenin for gender determination and two low-stutter, highly discriminating pentanucleotide STR markers. All sixteen loci are amplified simultaneously in a single tube and analyzed in a single injection. The PowerPlex 16 HS System is compatible with ABI PRISM 310, 3100 and 3100-Avant Genetic Analyzers and Applied Biosystems 3130, 3130xl, 3500 and 3500xL Genetic Analyzers.|

Generate Profiles with Samples that Previously Failed to Amplify: The PowerPlex(R), 16 HS System is more tolerant of PCR inhibitors than competing STR systems and the previous version of the PowerPlex(R), 16 System. Avoid costly and time-consuming sample cleanup.
Gain Confidence in Analysis of Limited Samples: Each lot is quality tested to produce full profiles from 100pg of DNA.
Achieve High Discrimination: The loci included in the PowerPlex(R), 16 HS System are more discriminating than competitive systems and are ideal for resolving partial matches or challenging familial cases.
Expect Concordance with Existing Databases: Primer sequences, dyes and ladders are all unchanged from the PowerPlex(R), 16 System.
Use a Complete System: The PowerPlex(R), 16 HS System includes size standard, amplification-grade water and Taq DNA polymerase already in the master mix. Simple to order, easy to use.
Automatically Assign Genotypes: Panels and bins text files are required for automatic assignment of genotypes using the GeneMapper(R), ID and ID-X software and are available for download.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store at -20°C.|U.S. Pat. Nos. 5,843,660, 6,479,235, 6,221,598 and 7,008,771, Australian Pat. No. 724531, Canadian Pat. Nos. 2,118,048 and 2,251,793 and other patents and patents pending. U.S. Pat. No. 6,238,863 and other patents and patents pending.STR loci are the subject of U.S. Pat. No. RE 37,984, German Pat. No. DE 38 34 636 C2 and other patents issued to the Max-Planck-Gesellschaft zur Förderung der Wissenschaften, e.V., Germany.Licensed under U.S. Pat. No. 5,587,287 and corresponding patents in other countries. For Research Use Only. Not for use in diagnostic procedures.Allele sequences for one or more of the loci vWA, FGA, D8S1179, D21S11 and D18S51 in allelic ladder mixtures is licensed under U.S. Pat. Nos. 7,087,380, 7,645,580, Australia Pat. No. 2003200444 and corresponding patent claims outside the US.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding