Promega

cAMP-Glo Assay, 300 Reactions

Varenummer: V1501
Kort informasjon 300 Reactions
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The cAMP-Glo Assay is a homogeneous, bioluminescent and high-throughput assay for measuring cAMP levels in cells. The cAMP-Glo Assay monitors cAMP production in cells in response to the effects of test compounds on G protein-coupled receptors (GPCR). GPCRs that couple with adenylate cyclase will increase or decrease intracellular cAMP. The assay is based on the principle that cyclic AMP (cAMP) stimulates protein kinase A (PKA) holoenzyme activity, decreasing available ATP and leading to decreased light production in a coupled luciferase reaction. The cAMP-Glo Assay can be performed in 96-, 384- or 1536-well plates. The cells are induced with a test compound for an appropriate period of time to modulate cAMP levels. After induction, cells are lysed to release cAMP, then the cAMP detection solution, which contains protein kinase A, is added. The Kinase-Glo Reagent is then added to terminate the PKA reaction and detect the remaining ATP via a luciferase reaction. Plates are read using a microplate-reading luminometer. Luminescence can be correlated to the cAMP concentrations by using a cAMP standard curve. The half-life for the luminescent signal is greater than 4 hours. This extended signal half-life eliminates the need for luminometers with reagent injectors and allows batch-mode processing of multiple plates.|

Fast and Easy to Use:
Assay can be completed in approximately 45 minutes.
Homogeneous.
Two steps following lysis of cells.
Excellent Signal-to-Noise Ratios:
Best signal:background ratio of all the cAMP assays.
Signal:Background more than200 (with cAMP), more than15 (on cells).
Easily scalable to 1536-well plate formats and beyond.
Proven Luminescent Technology:
Powered by Ultra-Glo™ Recombinant Luciferase.
No interference by fluorescent compounds.
Non-radioactive.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store the system at -20°C. Once prepared, the cAMP detection solution (cAMP-Glo™ Reaction Buffer with Protein Kinase A) should not be frozen. Once prepared, the Kinase-Glo(R) Reagent should be dispensed into aliquots and stored at -20°C. See the product label for the expiration date.|Patent Pending.U.S. Pat. Nos. 6,602,677, 7,241,584 and 8,030,017 and other patents and patents pending. U.S. Pat. No. 7,700,310 and other patents and patents pending.U.S. Pat. Nos. 7,083,911, 7,452,663 and 7,732,128 and other patents.U.S. Pat. No. 7,741,067 and other patents and patents pending.The method of recombinant expression of Coleoptera luciferase is covered by U.S. Pat. Nos. 5,583,024, 5,674,713 and 5,700,673.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding