Promega

MAO-Glo Assays

Varenummer: V1402
Kort informasjon 1 000 assays Sensitive Detection of Monoamine Oxidase (MAO) Activity. Luminescence-based method eliminates need for time-consuming analyses such as HPLC. Less MAO enzyme required than typical HPLC or fluorometric methods.
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The MAO-Glo Assay provides a homogeneous luminescent method for measuring monoamine oxidase (MAO) activity from recombinant and native sources and for testing the effects of test compounds on MAO activity. The MAO-Glo Assay is performed by incubating the MAO enzyme source with a luminogenic MAO substrate. The substrate of the MAO-Glo Assay is a derivative of beetle luciferin. Upon reaction with MAO, the derivative is converted into luciferin, which in turn reacts with luciferase to produce light. The amount of light produced is directly proportional to the activity of MAO. After the MAO reaction has been performed, the reconstituted Luciferin Detection Reagent is added. The reagent simultaneously stops the MAO reaction and initiates a stable glow-type luminescent signal with a half-life greater than 5 hours. This eliminates the need for strictly timed luminescent detection. The MAO-Glo Assay includes a luminogenic MAO substrate, two MAO Reaction Buffers (one that can be used with either MAO A or MAO B enzyme and one that is designed specifically for MAO B), a lyophilized Luciferin Detection Reagent and the Luciferin Detection Buffer. The user supplies the sample material containing MAO. Protocols are configured for multiwell plate formats but easily can be adapted for single-tube applications.|
Complete Solution: The MAO-Glo™ Assay with MAO-A contains monoamine oxidase A enzyme for convenient assessment of the effects of new chemical entities on MAO-A activity.Speed: The luminescence format eliminates the need for time-consuming analyses such as HPLC.Simplified Method: The simple "add and read" protocol makes the assay amenable to high-throughput screening in multiwell plates.Greater Sensitivity: Less MAO enzyme is required in these assays than in typical HPLC or fluorometric methods because of the enhanced sensitivity.No Fluorescence Interference: Luminescent output eliminates interference from fluorescent test compounds.Stable Signal: "Glow-type" luminescence provides a stable signal with a half-life of greater than 5 hours. This eliminates the need for strictly timed luminescent detection.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store MAO-A enzyme (Cat.# V1452) at -70°C. Store all other components at -20°C protected from light.|Patent Pending.U.S. Pat. Nos. 6,602,677, 7,241,584 and 8,030,017 and other patents and patents pending. The method of recombinant expression of Coleoptera luciferase is covered by U.S. Pat. Nos. 5,583,024, 5,674,713 and 5,700,673.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding