Promega

MultiTox-Fluor Multiplex Cytotoxicity Assay, 5x10ml

Varenummer: G9201
Kort informasjon 5 × 10 ml A Fluorescent Assay That Measures Both Cell Viability and Cytotoxicity. Assay normalizes data for cell number. Reduces false-positive and false-negative results
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The MultiTox-Fluor Multiplex Cytotoxicity Assay is a single-reagent-addition, homogeneous, fluorescent assay that measures the number of live and dead cells simultaneously in culture wells. The assay simultaneously measures cell viability and cytotoxicity by detecting two distinct protease activities. The live-cell protease activity is restricted to intact viable cells and is measured using a fluorogenic, cell-permeant peptide substrate (GF-AFC Substrate). The substrate enters intact cells where it is cleaved to generate a fluorescent signal proportional to the number of living cells. This live-cell protease activity marker becomes inactive upon loss of membrane integrity and leakage into the surrounding culture medium. A second, cell-impermeant, fluorogenic peptide substrate (bis-AAF-R110 Substrate) is used to measure dead-cell protease activity that has been released from cells that have lost membrane integrity.|

Measure the Number of Live and Dead Cells in Culture: Homogeneous, "add-mix-measure" protocol eliminates parallel plate processing and reduces cell culture costs.

Normalize Data for Cell Number: The ratio of live:dead cells is independent of cell number and normalizes data. Data normalization for cell number makes results more comparable well-to-well, plate-to-plate, day-to-day.

Reduce False-Positive and -Negative Results: Complementary live- and dead-cell measures with independent chemistries serve as internal controls for each other.

Get More Data from Every Well: Multiplex the MultiTox-Fluor Assay with most Promega bioluminescent cell-based apoptosis or genetic reporter assays.

Reduce Assay Variability: The homogeneous "add-mix-measure" protocol avoids the cumulative error associated with multistep protocols.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store at -20°C.|Patent Pending.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding