Promega

Luciferase Assay System, 10-Pack, 1000 assay

Varenummer: E1501
Kort informasjon 1,000 assays
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The Luciferase Assay System is an extremely sensitive and rapid reagent for quantitation of firefly luciferase. Linear results are seen over at least 8 orders of magnitude of enzyme concentration, and the patented technology incorporated into this assay system allows measurement of less than 10(-20) moles of luciferase under optimal conditions. Generally, 100-fold greater sensitivity can be achieved over chloramphenicol acetyltransferase (CAT) assays. The Luciferase Assay Reagent generates light that is nearly constant for at least 1 minute and so is compatible with measuring firefly luciferase in a single-tube luminometer or in a multiwell plate luminometer with an auto-injector. The Luciferase Assay System is a nonhomogeneous assay system; the cells containing the luciferase must be lysed before reagent addition. Glo Lysis Buffer (Cat.# E2661), Cell Culture Lysis Reagent (Cat.# E1531), Passive Lysis Buffer (Cat.# E1941) and Reporter Lysis Buffer (Cat.# E3971) can be used with the Luciferase Assay System for reporter quantitation in mammalian cells. The Luciferase Assay System also can be used for quantitation in plant and bacterial cells, but only Cell Culture Lysis Reagent is suitable for these applications. Reporter Lysis Buffer enables firefly luciferase, CAT and beta-galactosidase assays to be performed from the same cell extract. In some kits the lysis buffer is included, and in others it must be purchased separately.|

Linear: Eight or more orders of magnitude of enzyme concentration.
Sensitive: To 10-20 moles of luciferase.
Fast: Perform cell lysis, sample preparation and assays in as little as 5 minutes.
Convenient: Reporter Lysis Buffer enables luciferase, CAT and β-galactosidase assays to be performed from the same cell extract.
Simple Assay Procedure: Eliminates the need for autoinjection devices and rapid mixing protocols when using single-tube luminometers.
Versatile: Luminometer preferred, but not required; adaptable to scintillation counters.
Safe: Non-radioactive.
Superior: High performance compared to competitors' luciferase assays.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store system at -20°C. Store Cat.# E1483 at -70°C. Reporter Lysis Buffer (Cat.# E3971) may be stored at room temperature. Store Cat.# E2661 at 4°C. For long-term storage, freeze Cat.# E2661 at -20°C or -70°C.Cat.# E1500, E4030, E1501, E4530, E4550, E1483: U.S. Pat. Nos. 5,641,641 and 5,650,289.Cat.# E1500, E4030, E1501, E4530, E4550, E1483: The method of recombinant expression of Coleoptera luciferase is covered by U.S. Pat. Nos. 5,583,024, 5,674,713 and 5,700,673.Cat.# E1500, E4030, E1501, E4530, E4550, E1483: Certain applications of this product may require licenses from others.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding