Promega

CytoTox-Glo Cytotoxicity Assay, 5 x 10ml

Varenummer: G9291
Kort informasjon 5 × 10 ml
  • Produktinformasjon
  • Relaterte produkter
  • Alternative produkter
  • Spesifikasjoner
The CytoTox-Glo Assay is a luminescent cytotoxicity assay that measures the relative number of dead cells in cell populations. The CytoTox-Glo Assay measures the extracellular activity of a distinct intracellular protease activity (dead-cell protease) when the protease is released from membrane-compromised cells. A luminogenic cell-impermeant peptide substrate (AAF-aminoluciferin) is used to measure dead-cell protease activity. The liberated aminoluciferin product is measured as glow type luminescence generated by Ultra-Glo Recombinant Luciferase provided in the assay reagent. The AAF-aminoluciferin substrate cannot cross the intact membrane of viable cells and does not generate any appreciable signal from the live-cell population. The amount of luminescence directly correlates with the percentage of cells undergoing cytotoxic stress. With the addition of a lysis reagent (provided), the CytoTox-Glo Assay also can deliver the luminescent signal associated with the total number of cells in each assay well. Viability can be calculated by subtracting the luminescent dead-cell signal from the total luminescent value, thus allowing you to normalize assay data to cell number and mitigate assay interferences that may lead to erroneous conclusions. The cytotoxicity protease biomarker is constitutive and conserved across cell lines, and the CytoTox-Glo Assay demonstrates excellent correlation with other methods of assessing cell viability.|
Measure the Relative Number of Dead Cells in Culture: Measure cytotoxicity by adding a single reagent with the homogeneous "add-mix-measure" protocol.Distinguish Between Small Differences in Viability: The assay provides a linear response and can distinguish between small differences in viability across the entire spectrum of cytotoxicity, from modest cytotoxicity (100 to 95% viability) to profound cytotoxicity (5 to 0% viability).Normalize Data for Cytotoxicity: Data normalization for dead-cell number makes results more comparable well-to-well, plate-to-plate and day-to-day.Measure the Relative Number of Remaining Viable Cells Using a Total Lysis Protocol: Correlate increased cytotoxicity with a reduction in viable cells.Improve your Data: Reduce statistical probability of false-positives (or false-negatives), and eliminate fluorescence interference issues with a stable luminescence readout.

Det finnes ingen relaterte produkter.

Det finnes ingen alternative produkter.
Ekstra spesifikasjoner
Store at -20°C, protected from light.|Patent Pending.U.S. Pat. Nos. 6,602,677, 7,241,584 and 8,030,017 and other patents and patents pending. The method of recombinant expression of Coleoptera luciferase is covered by U.S. Pat. Nos. 5,583,024, 5,674,713 and 5,700,673.

Kontaktperson(er) til dette produktet

Christine Rindal Ibra 944 34 009 christine.rindal.ibra@nmas.no
Claudia Emmanuel 951 51 950 claudia.emmanuel@nmas.no
Monica Laukas 404 40 960 monica.laukas@nmas.no

Kontakt oss

Ønsker du mer informasjon om våre produkter eller tjenester?
Fyll inn dine kontaktopplysninger og hva saken gjelder, så tar vi kontakt med deg.

Kontaktskjema
Bedrift
Telefon
E-post
Melding